We use cookies and similar technologies to make our website work, run analytics, improve our website, and show you personalized content and advertising. Some of these cookies are essential for our website to work. For others, we won’t set them unless you accept them. To find out more about cookies and how to manage cookies, read our Cookie Policy.

Solving the Biggest Problem in Seawater Desalination

by Johanna Lee

When Dr. Motasem Abushaban started graduate school in 2012 at the IHE Delft Institute for Water Education in the Netherlands, he knew what he wanted to study. He grew up in Palestine, where there is a severe water crisis. “We don't have sufficient safe fresh water. It seems that our only option is to desalinate seawater in order to have drinkable water. That's why I was interested in seawater desalination,” he says. Water scarcity is a global issue, and desalination has become the sole water source for many coastal countries without access to freshwater. The main goal of Motasem’s research is to solve the most serious problem in the operation of desalination: membrane biofouling.

Motasem Abushaban IHE Delft biofilm prevention

Dr. Motasem Abushaban, former graduate student at IHE Delft.

 

The Problem of Membrane Biofouling

Most desalination facilities produce drinking water through reverse osmosis (RO), in which seawater is passed through RO membrane filters, removing salt and biomass from seawater. Membrane biofouling occurs when bacteria from seawater sticks to the RO membrane and forms a layer of biofilm, reducing water flow. As biofilm clogs the pores on the membrane, more pressure is required for water to pass through, reducing production efficiency and raising operating costs. Once the membrane is severely clogged, it needs to be cleaned or replaced—both time-consuming and costly operations. “It’s not only about the cost of the membrane or the cost of operation. There’s also an environmental impact,” says Motasem. To clean the biofilm, you need to use cleaning chemicals, which enter the membrane system and are discharged back into the sea, potentially harming the marine environment.

The best way to minimize biofilm from forming in the first place is to reduce the amount of biomass and nutrients in seawater entering the RO filter. This can be done by improving pretreatment procedures. But how can you tell whether the pretreatment process is working? Motasem realized that he needed a fast method to effectively measure bacterial growth potential in seawater. 

water glo desalination RO membrane

Measuring Biomass in Seawater

There are several methods for measuring bacteria in seawater. The most common method, heterotrophic plate count (HPC), involves spreading the water sample on a culture plate, waiting for bacterial colonies to grow, and then counting the number of colonies. Unfortunately, this growth period can take up to 21 days. By the time you get results, biofilm may have already clogged the membranes. Another issue with HPC is that you can only count the bacterial colonies capable of growing on a culture plate (1–10% of all bacteria species), which means a majority of bacteria are missed from this method.

A faster method called flow cytometry involves running samples through a specialized instrument that automatically counts the number of bacteria in the sample. However, the number of bacteria does not necessarily reflect the biological activity of bacteria. “We can have one million bacteria in seawater, but it means nothing if these bacteria are not active,” says Motasem. Another issue with flow cytometry is that it often underestimates the number of bacteria if they are clumped together—it might count a clump of a few thousand bacteria as one.

The ideal method for Motasem’s application would be fast, reliable and measures all active biomass. This is possible with an assay that measures the concentration of a tiny molecule called adenosine triphosphate (ATP)—the energy currency of all living cells. “Through ATP testing, we can know the activity of the bacteria. Maybe there’s only 1,000, but they could be very active,” says Motasem. He found that there were ATP testing kits available for testing freshwater, such as drinking water. However, they did not work with seawater because salt interfered with the reaction. “We were looking for a way to measure ATP in seawater because it's clearly a very good method; very fast, very robust. It gives a lot of information within seconds.” 

Monitoring biomass to prevent membrane fouling

Dr. Motasem Abushaban collects seawater samples from a sampling point of a full-scale seawater desalination plant in Oman.

 

Developing an ATP Assay for Seawater

While researching ATP, Motasem heard of a seminar held at Promega. He attended the seminar and talked with Promega representatives about the need for an ATP test that works for seawater. “The Promega people were very excited about it. They started having some ideas.” Motasem began collaborating with Promega Senior Research Scientist, Dr. Subhanjan Mondal, to develop the perfect reagents for his needs. “We initially tried to repurpose existing products. But we soon realized we needed to completely redesign the kit,” says Subhanjan.

Promega reformulated the reagents and shipped them to Motasem for testing. It took two years and ten on-site visits until the reagents were finalized and developed into a water testing kit called “Water-Glo”. The method involved directly adding lysis reagent into a sample of seawater, incubate for 5 minutes, add detection reagent, then measure signal with a luminometer. Motasem tested this direct method in three full-scale desalination plants located in Oman, United Arab Emirates and Australia, and another pilot-scale plant in the Netherlands. “It was simple, fast and accurate,” says Motasem. The Water-Glo™ kit also detects much lower concentrations of ATP (0.3 ng/L) than other kits.

Promega scientist testing Water glo ATP Assay

Dr. Subhanjan Mondal working in the lab.

 

water glo desalination study membrane fouling

See Motasem's published data:
Direct Method for Measuring ATP in Seawater

Download the Paper

Motasem was pleased with this method, but he didn’t stop there. A problem with directly adding lysis reagent into seawater is that seawater conditions (e.g., iron, salinity and pH levels) can interfere with ATP detection. Thus, additional calibration is required every time seawater conditions change, which can be a tedious process. Motasem worked with Subhanjan to eliminate the calibration step altogether while using the same Water-Glo™ reagents. To do so, they developed a filtration-based method in which seawater is first pushed through a filter that captures the biomass. Lysis reagent is then used to extract ATP from the captured biomass. This filtration method was successfully used to monitor bacterial growth potential of seawater throughout pretreatment and filtrations steps in desalination plants.

The direct method and filtration method are useful in different situations. The direct method works best for monitoring the same seawater over time, when there are no changes in the water composition or matrix. However, if you are monitoring water as it goes through the pretreatment and desalination process, water properties change with added chemicals or filtration. In this case, the filtration method is preferable since you don’t have to prepare multiple calibration curves. 

Water Glo kit and GloMax prevent membrane fouling

Dr. Motasem Abushaban (IHE Delft) and Duddy Oyib (Promega) working together to test Water-Glo™ reagents using the GloMax® Navigator Microplate Reader.

 

water glo desalination study membrane fouling

See Motasem's published data:
Filtration Method for Measuring ATP in Seawater

Read the Paper

The Future of Membrane Fouling Prevention

Motasem is now using the Water-Glo™ Kit to test seawater in desalination plants around the world. His goal is to collect as much data as possible from varying samples of seawater to determine the threshold bacterial growth potential that prevents membrane fouling. Currently, there is no standard biological method to monitor pretreatment of desalination plants. Motasem hopes that once this threshold value is determined, it can become an industry standard for membrane biofouling prevention. Plant operators can continuously monitor pretreatment using Water-Glo and quickly decide whether additional pretreatment is required. “Water-Glo allows you to get real-time results instead of snapshots in time. With more data, you can be proactive instead of reactive,” says Subhanjan.

Motasem is hopeful that his research will have a real impact on the industry. Solving the problem of membrane biofouling will benefit the operation of desalination plants around the world. It will also help millions of people in his home country and other regions that need access to clean, affordable water.

assess-biomass-viability-in-water-overview

See more resources on water testing and ATP assays.

Learn More
water-glo-information

 

 

If you have questions about the Water-Glo™ Kit, please contact us at: applied@promega.com