Promega's Cookie Policy

We use cookies and similar technologies to make our website work, run analytics, improve our website, and show you personalized content and advertising. Some of these cookies are essential for our website to work. For others, we won’t set them unless you accept them. To find out more about cookies and how to manage cookies, read our Cookie Policy.

Casework Direct System

DC4561_Casework-Direct-System_3
customize-this-small

Rapidly Process Sexual Assault Evidence and Low Abundance DNA Samples

  • No-wash protocol maximizes the chance of recovering DNA from trace samples
  • Quickly generates lysates that are compatible with PowerQuant®, Plexor® HY and PowerPlex® Systems
  • Useful for Y-screening and selection of evidentiary samples for STR testing
  • Note: The Casework Direct System (Cat.# DC4560, DC4561) replaces the custom version of the Casework Direct Kit, Custom (Cat.# AX4560). No changes have been made to the product composition and, therefore, no performance changes are expected during the migration of the product from the custom to catalog version.

Size

Catalog number selected: DC4560

Please Enquire
This product is discontinued
This product is available under our Early Access program - Learn More
This product is available under our Catalog (FT) program - Learn More
Casework Direct System
100ml
Your price:
Change Configuration

Rapidly Process Challenging Sample Types

The sheer volume of property crime and sexual assault evidentiary samples submitted to forensic laboratories has compelled many laboratories to actively seek out better solutions for processing these challenging sample types. The Casework Direct System is designed to rapidly process swabs from casework samples or cuttings of sexual assault swabs and stained clothing. (Read more in this white paper—download article.)

Unlike competing kits, lysates generated with the Casework Direct System are compatible with our quantification and STR amplification product lines. These lysates may be amplified with the PowerQuant® or Plexor® HY Systems to screen sexual assault samples for male DNA and to normalize human template for STR amplification with one of the PowerPlex® STR Systems. 

When used with the PowerQuant® System, valuable workflow information such as the presence/absence of male DNA, degradation or potential PCR inhibition is provided.

Quantify lysates with the PowerQuant System

Learn more about how the Casework Direct System and the PowerQuant® System can help improve processing efficiency for sexual assault evidence kits (SAEK).

Forensic Grade logo

Promega forensic products are manufactured in alignment with the ISO 18385 standard.This standard ensures minimal risk of human DNA contamination for products used to collect, store and analyze biological materials for forensic purposes. Learn more.

How It Works

Casework Direct workflow part 1
Casework Direct workflow part 2

Add 100–400µl of Casework Direct Solution along with a swab or cutting in the CW Spin Basket assembly, vortex for 5–10 seconds and incubate at 70°C for 30 minutes. Vortex again for 5–10 seconds, and centrifuge at room temperature for 5 minutes at maximum speed in a microcentrifuge to collect the lysate in the 1.5ml microcentrifuge tube. Carefully remove the CW Spin Basket containing the swab or cutting, and discard the spin basket. Quantify 2µl of the lysate using PowerQuant® System or Plexor® HY System. Amplify up to 15µl of the lysate using a PowerPlex® System.

Y-Screening Application

Traditional serology screening of sexual assault samples is laborious and allows limited sensitivity in comparison to male DNA detection by amplification. Using the Casework Direct no-wash protocol, labs can reduce both cost (labor and reagents) as well as the potential DNA loss typically seen in the DNA extraction step. Additionally, conventional screening results offer analysts little predictive power as to what DNA profile may result. Recognizing the limitations and challenges associated with traditional serology methods, new SWGDAM recommendations are now instructing the use of a “Direct to DNA” approach where DNA analysis is performed before serology to maximize the chances of obtaining CODIS eligible profiles. The figure below demonstrates the successful recovery of male DNA from a series of samples that were processed using the Casework Direct System.

Detection of male DNA in semen dilution series

Detection of male DNA in semen dilution series. Dilutions of human semen were spotted on cotton swabs. 400µl of Casework Direct Solution was added to the swab placed in a spin basket assembly, incubated at 70°C for 30 minutes and centrifuged at max speed for 5 min to recover the lysate. 2µl of the lysate was used to quantify the amount of human amplifiable DNA using PowerQuant® System and 0.5ng or maximum volume of lysate was used for STR amplification using PowerPlex® Fusion and PowerPlex® Y23 System. The amplified products were electrophoresed on 3130xl using POP4 with 3kV, 5 sec injection and analyzed on GeneMapper® IDv3.2 with an analysis threshold of 50 RFU. The percentage of alleles called is shown on the left axis and the corresponding template amount on the right y-axis. Less than 0.5ng template amount was available for 1:100 and 1:1000 dilution samples. Profiles were called at all dilution except 1:1000 for PowerPlex® Fusion and Y23. 

Casework Trace DNA Samples

For the last few years, law enforcement agencies have seen an uptick in property crime evidence submissions, resulting in the need to use significant laboratory resources to test evidence for trace DNA, such as DNA from microscopic skin cells that naturally rub off when an object, like a car steering wheel, is touched. When DNA is found at a property crime scene, laboratories are often able to match it to a known offender’s sample in CODIS, the national DNA database.

Integration of the Casework Direct System into a laboratory’s workflow provides a rapid and cost effective means to generate, with minimal hands-on time, high quality STR profiles from precious, low abundance samples. When used with the PowerQuant® System, valuable workflow information such as the presence/absence of male DNA degradation or potential PCR inhibition is provided. STR results from several mock casework samples are provided below.

CWD with PowerPlex Fusion
CWD with PowerPlex Y23

Casework Direct Solution for trace DNA samples. Cotton swabs were used to collect trace DNA samples from steering wheel, computer mouse and cell phone surfaces. 400µl of Casework Direct Solution was added to the swab placed in a spin basket assembly, incubated at 70ºC for 30 minutes and centrifuged at 16,000 × g for 5 minutes to recover the lysate. 2µl of the lysate was used to quantify the amount of human amplifiable DNA using PowerQuant® System and 0.5ng or maximum volume of lysate was used for STR amplification using PowerPlex® Fusion and PowerPlex® Y23 Systems. The amplified products were electrophoresed on the Applied Biosystems® 3500xL Genetic Analyzer using POP4 with 3kV, 5 second injection and analyzed on GeneMapper® IDv3.2 with an analysis threshold of 50 RFU.

 

Additional Information

Casework Direct Developmental Validation WP108

Rapid Casework Sample Processing

This white paper describes the developmental validation of the Casework Direct Kit, Custom, for rapid processing of samples ranging from swabs to trace DNA samples.

Read White Paper
Property Crime Samples Brochure BR327

Rapid, Cost-Effective Processing of Property Crime Samples

This brochure provides an overview on how to use the Casework Direct System to generate high-quality STR profiles from precious, low-abundance samples.

Download PDF
Y Screening Brochure BR328

Improve SAEK Processing Efficiency

This brochure highlights using the Casework Direct System for a "Direct-to-DNA" approach, to maximize the chances of obtaining CODIS-eligible profiles.

Download PDF
Casework Direct Stability Testing Wp114

Stability of Lysates

This white paper presents the results of long-term storage testing at 4°C and 28°C, as well as freeze-thaw studies, of lysates prepared with the Casework Direct System.

Read White Paper

Specifications

You are viewing: DC4560 Change Configuration

What's in the box?

Item Part # Size Available Separately
1-Thioglycerol A208A 1 × 75μl
5X AmpSolution™ Reagent DM123A 1 × 500μl View Product

Casework Direct Reagent

DM456A 1 × 100ml

Water, Amplification Grade

DW099A 5 × 1,250μl View Product

Certificate of Analysis

Search by lot number

Use Restrictions

Not For Medical Diagnostic Use.

Storage Conditions

EE

Specifications

You are viewing: DC4561 Change Configuration

What's in the box?

Item Part # Size Available Separately
1-Thioglycerol A208A 1 × 75μl
5X AmpSolution™ Reagent DM123A 1 × 500μl View Product

Casework Direct Reagent

DM456B 1 × 10ml

Water, Amplification Grade

DW099A 2 × 1,250μl View Product

Certificate of Analysis

Search by lot number

Use Restrictions

Not For Medical Diagnostic Use.

Storage Conditions

EE

Let's find the product that meets your needs.

Talk to a Scientist

scientist-uk-manos

Manos

UK