The CytoTox 96® Non-Radioactive Cytotoxicity Assay is a colorimetric alternative to radioactive cytotoxicity assays. The assay quantitatively measures lactate dehydrogenase (LDH), a stable cytosolic enzyme that is released upon cell lysis, in much the same way as [51Cr] is released in radioactive assays. Released LDH in culture supernatants is measured with a 30-minute coupled enzymatic assay that results in the conversion of a tetrazolium salt (INT) into a red formazan product. The amount of color formed is proportional to the number of lysed cells. Visible wavelength absorbance data are collected using a standard 96-well plate reader. The assay can be used to measure membrane integrity for cell-mediated cytotoxicity assays in which a target cell is lysed by an effector cell, or to measure lysis of target cells by bacteria, viruses, proteins, chemicals, etc.
The CytoTox 96® Non-Radioactive Cytotoxicity Assay requires no radioactive waste disposal or [51Cr] and eliminates labeling of target cells prior to conducting experiments. Standard equipment can be used to collect absorbance (visible wavelength) data with a standard 96-well plate reader. The assay can be used for a variety of applications including measurement of 1) cell-mediated cytotoxicity; 2) chemical-mediated cytotoxicity; and 3) total cell number. A highly sensitive assay, it can reveal early, low-level damage to cell membranes that is often missed with other methodologies.
Protocols
Specifications
Catalog Number:
What's in the box?
Item | Part # | Size |
---|---|---|
Substrate Mix |
G179A | 5 × 1 vial |
Assay Buffer |
G180A | 1 × 60ml |
LDH Positive Control |
G181A | 1 × 25μl |
Lysis Solution, 10X |
G182A | 1 × 5ml |
Stop Solution |
G183A | 1 × 65ml |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
Store LDH Positive Control, Lysis Solution (10X) and Stop Solution at 4°C.
Resources
No related resources available
Related Products
Similar Products
LDH-Glo™ Cytotoxicity Assay
Bioluminescence-based LDH assay for sensitive detection of cytotoxicity in samples low in cell number, including 3D microtissues.
J2380, J2381
CytoTox-Fluor™ Cytotoxicity Assay
A single-reagent-addition, homogeneous, fluorescent assay that measures the relative number of dead cells in cell populations.
G9260, G9261, G9262
CytoTox-ONE™ Homogeneous Membrane Integrity Assay
A homogeneous, LDH-based fluorometric method for quantifying non-viable cells.
G7890, G7891, G7892
CellTox™ Green Cytotoxicity Assay
Measures changes in membrane integrity. Kinetically monitors cytotoxicity up to 72 hours with multiplex capability.
G8741, G8742, G8743, G8731
Frequently Used With
Caspase-Glo® 3/7 Assay System
An easy-to-use, plate-based luminescent assay for detecting caspase-3/7 activity.
G8090, G8091, G8093, G8092, MG1010
Caspase-Glo® 8 Assay Systems
Measure caspase-8 activity with this homogeneous, luminescent assay.
G8200, G8201, G8202
CellTiter-Blue® Cell Viability Assay
Monitor cell viability with this homogeneous, resazurin, fluorescent assay.
G8080, G8081, G8082